Home

Order Online

Product Groups

Gas Analyzers
Diesel Smoke Meters
OBD II Scan Tools
Shop Management Software
Wireless Diagnostics
Business Profitability
Pocket PC Products
Pocket GasTM
Pocket OBDTM
Pocket SmokeTM
Wireless Diagnostics
PC Based Products
Gas Analyzers for Desktops and Laptops
Diesel Smoke Meters for Desktops and Laptops
Shop Management Software
Wireless Diagnostics
Certified Safety/ Emissions/OBD II
Miscellaneous
Software / Demos
OEM Products and Emissions
Custom Product Development
Press Releases
Links
About Us

Applus+ AutoLogic Inc. has two different smoke meters that are widely used for testing and diagnosing diesel engines for opacity levels. The J1667 packages include a meter that sits at the end of the stack of a heavy-duty vehicle and is designed to meet US and Canadian SAE J1667 specifications. The MOT packages include a partial flow smoke meter that is designed to meet European specifications for testing light duty vehicles. Each model comes with the latest Windows diagnostic software that enables vehicles to be quickly tested and diagnosed. Each model is available as a portable unit connected to a laptop computer or as a complete stand-alone meter with computer workstation. These models are approved in many countries around the world and provide advanced software for diagnosing emissions related problems.

The software allows units to be displayed in Density (m -1 ), K, or Percent opacity at different path lengths. Both full and partial flow units are available. The paragraphs below show the advantages of Heavy Duty Diagnostic Center™.

Light Duty MOT

The light duty MOT diesel smoke meter is designed to meet the opacity measurement requirements of PTB in Germany, M.O.T in the UK, ISO 3173 and is approved in many countries around the world. It is available in both 110 VAC and 220 / 240 VAC. The package includes heavy-duty hose and stainless steel probe. The hardware utilizes a green light LED (550 - 570 nm) light and compensates the light source for temperature variations. The unit also includes calibration filter to assure accurate opacity measurement. It is designed to run as a stand-alone meter to be used with a portable or laptop computer or is also available with complete heavy-duty PC stand. This model is recommended for use in light duty testing or applications where a partial flow meter is recommended.

Heavy Duty SAE J1667

The heavy-duty J1667 diesel smoke meter is used in the stack of the vehicle under test. This meter meets or exceeds the SAE J1667 specifications used in the US and Canada for testing heavy-duty vehicles and is approved in many states and provinces.The meter comes standard with the latest in Windows software for testing and diagnostics as described below. The meter operates from 12 volts DC or internal, included battery and is light and quick to use. The meter design is durable and is made of lightweight high strength steel. The meter includes telescopic pole for effortless installation of the smoke head in the vehicle's exhaust stack.

  • Measures Diesel Smoke In % and Density (m -1 , K)
  • Meets or exceeds US SAE J1667 and European MOT standards
  • Contact manager gives quick storage and retrieval of customer's names and phone numbers
  • Large amount of opacity and customer data is stored. Look up the readings days later after testing for diagnostics or quick comparison of vehicle to vehicle.*
  • Editable Specification database to enable easy comparison of test results to pass / fail limits.
  • Uses industry standard display parts to eliminate expensive service requirement

  • Utilizes the latest Windows features to display and record smoke in a wide variety of options.
  • Easy to use. Does not require extensive Windows knowledge to operate.
  • Designed to meet international standards with language capabilities, international time/date formats, etc.

  • Screens include certified testing screens, configuration screens for opacity percentage or density, large easy to read digital meter screens for diagnostics, calibration screens, and built in smoke strip chart recorder for viewing of opacity trends as the vehicles accelerates.

  • Large database allows the software to keep complete customer and vehicle history thus giving quick and easy comparisons from vehicle to vehicle.
  • Designed to be utilized with gas measurement software and heavy duty shop management software.

Specifications

Light Duty MOT
Voltage: 110/220/240 VAC 20/60 Hz
Measurement Range: -0.0% to +100.0%
Ambient Temp: -2 - +55 Degrees C
Operating Temp: +28 - +131 Degrees F
Resolution: 0.1%
Weight: 12.3 kilos (27.0 lbs)
Path Length: 0.430 Meters

Heavy Duty J1667
Voltage: 12 VDC
Measurement Range: -0.0% to +100.0%
Ambient Temp: -2 - +55 Degrees C
Operating Temp: +28 - +131 Degrees F
Resolution: 0.4%
Weight: 2.3 kilos (5.0 lbs)
Path Length: 5 inches (variable to J1667)

 

 